Skip to main content

mmv-sa-advanced-hero.jpg

Recommended source size

1200 × 1600 px

Advanced Microhardness Tester

MMV-SA Advanced Semi-Automatic Microhardness Tester

Choose MMV-SA Advanced for PLC-controlled semi-automatic testing when the laboratory needs controlled operation now and a route to later automation.

Vickers & Knoop10 gf-1 kgComputerized Measurement

Designed for Future Automation

MMV-SA Advanced is intended for laboratories that need PLC-controlled semi-automatic testing today but expect throughput and automation requirements to grow.

In its present configuration, the motorized auto turret, touchscreen HMI and computerized measurement workflow reduce routine handling and make repeated testing easier to standardize across operators.

Its upgradeable architecture also provides a planned route toward automatic operation. Options are added only when required, helping an expanding laboratory retain its initial platform rather than replacing it as workload develops.

mmv-sa-advanced-upgrade.jpg

Recommended source size

1200 × 900 px

MMV-SA Advanced
Motorized XY Stage
Automatic Operation Upgrade
Programmed Positioning
Computerized Measurement
Automatic Reporting

Upgrade elements are configuration pathways, not standard functions included with the semi-automatic machine.

Typical Applications

Industrial Laboratories

A practical application for routine Vickers or Knoop measurement on properly prepared samples.

Case Depth

Manual indent placement along a prepared cross-section records the case-depth hardness profile.

Heat Treatment

Helps assess hardness response after heat treatment on correctly prepared and supported specimens.

Automotive

Suited to routine hardness checks on prepared production components and sectioned parts.

Gear Industry

Suited to routine hardness checks on prepared production components and sectioned parts.

Aerospace

A practical application for routine Vickers or Knoop measurement on properly prepared samples.

Failure Analysis

Localized hardness results add material evidence to a broader failure investigation.

Key Technical Features

mmv-sa-advanced-technical-features.jpg

Recommended source size

1200 × 900 px

  • Test Loads: 10 gf-1 kg standard load range for Vickers and Knoop testing.

  • Objectives: 10x and 40x objectives for indentation setup and measurement review.

  • Test Table: 100 x 100 mm table with 25 mm X-Y travel.

  • Hardness Scale: Vickers and Knoop workflows according to configured indenter setup.

  • Computerized Measurement: Integrated camera connectivity sends the indentation image to DeXel-Hard for measurement, reporting and data management. This functionality is standard on all computerised models.

  • Motorized Auto Turret: Automatic objective and indenter switching through the control system.

  • PLC Control: PLC-based machine control for semi-automatic industrial operation.

  • Touchscreen HMI: Touchscreen HMI for method selection and machine control.

  • Upgradeable Architecture: Future upgrade path toward fully automatic operation.

Optional Features & Accessories

mmv-sa-advanced-accessory-1.jpg

Recommended source size

300 × 200 px

Additional Test Loads

Optional 5 gf, 1 kg, 2 kg and 3 kg load configurations where applicable.

mmv-sa-advanced-accessory-2.jpg

Recommended source size

300 × 200 px

6 Position Turret

Optional six-position turret for additional objectives and indenters.

mmv-sa-advanced-accessory-3.jpg

Recommended source size

300 × 200 px

Motorized XY Stage

Stage option for programmed positioning, traverse testing and automatic measurement routines.

mmv-sa-advanced-accessory-4.jpg

Recommended source size

300 × 200 px

Certified Hardness Test Blocks

Reference blocks for Vickers and Knoop verification during routine laboratory checks.

mmv-sa-advanced-accessory-5.jpg

Recommended source size

300 × 200 px

Additional Objectives

Objective options for alternate magnification, indentation size and sample review requirements.

mmv-sa-advanced-accessory-6.jpg

Recommended source size

300 × 200 px

Knoop Indenter

Knoop indentation capability for thin layers, coatings and selected material evaluations.

mmv-sa-advanced-accessory-7.jpg

Recommended source size

300 × 200 px

Universal Sample Holders

Sample holding options for mounted specimens, sections and varied laboratory geometries.

mmv-sa-advanced-accessory-8.jpg

Recommended source size

300 × 200 px

Special Fixtures

Application-specific fixtures for repeat positioning, unusual sample shapes or sectioned parts.

MMV-M

Manual diagonal measurement for economical, operator-controlled routine testing.

View Model

MMV-D

Digital diagonal measurement for faster routine hardness readings.

View Model

MMV-SA Entry

Entry semi-automatic platform with motorized turret and touchscreen control.

View Model

MMV-SA Advanced

PLC-based semi-automatic testing with an upgrade path toward automation.

View Model

MMV-A

Automatic testing platform for programmed traverses, mapping and batch work.

View Model

MMV-AL

Closed-loop automatic system for repeatability-focused testing workflows.

View Model

MMV-SL Special Load Series

Customizable micro and macro Vickers platform for extended loads and large samples.

View Model

Sample Preparation Equipment

Cutting, mounting, grinding and polishing equipment for reliable hardness-test specimens.

Explore

Metallurgical Microscopy Systems

Microscope systems for microstructure observation and indentation verification.

Explore

Image Analysis Systems

Measurement, reporting and documentation software for metallurgical laboratories.

Explore

Metallography Consumables

Consumables supporting consistent specimen preparation before hardness testing.

Explore

Discuss MMV-SA Advanced for your laboratory

Share the specimen, required load range, test pattern and reporting requirement. Conation will confirm the appropriate configuration.

Request Quote