Contamination Extraction & Filtration Systems
Compare extraction methods, filtration arrangements and system formats.
Learn MoreTechnical Cleanliness
PLC-controlled cabinets for repeatable contamination extraction on critical components, with stored recipes and controlled rinsing cycles.

Automatic Extraction Workflow
A typical automatic cabinet workflow connects programmed extraction to downstream analysis.
Position the part securely in the rinsing chamber.
Recall the approved pressure, time and cycle settings.
Run the programmed rinsing or ultrasonic cycle.
Capture released contamination on the selected membrane.
Prepare the membrane for stable measurement.
Measure particle count, size and distribution.
Record results against the applicable limit.
These cabinets suit laboratories that need controlled extraction cycles, repeatable methods and documented work to ISO 16232 or OEM requirements.
Choose the automatic cabinet model that matches the extraction method, component size and required level of process control.
Final model selection depends on extraction method, component size, ultrasonic need and handling requirement.
Spreadsheet-backed comparison for the automatic cabinet models.
Scroll horizontally to compare all models.
| Criteria | CTC-S10 | CTC-SU10 |
|---|---|---|
| Extraction method | Pressure rinsing, Internal Rinsing | Pressure rinsing, Internal Rinsing, Ultrasonic cleaning |
| Automation | PLC controller, 7" HMI touchscreen | |
| Rinsing chamber | 1000X700X700 mm | 1200X1000X700 |
| Max component size | 700X400X300 mm | 700X400X300 mm pressure rinsing; 400X300X300 mm ultrasonic |
| Max component weight | 50 kg | 50 kg / 10 kg |
| Manipulator adaptability | Yes | No |
| Laminar flow adaptability | Yes | |
Share the application, required range and operating conditions. An applications engineer will review the appropriate configuration.
Discuss the ComparisonTypical component groups where controlled extraction and traceable results are essential.
Standards and OEM requirements guide extraction method, automation and reporting.
Move between extraction system families without returning to the main overview.
Continue from controlled extraction into filtration, particle analysis, gravimetry or a controlled laboratory environment.
Compare extraction methods, filtration arrangements and system formats.
Learn MoreMeasure, classify and document particles collected after extraction.
Learn MoreDetermine contaminant mass from a prepared and conditioned membrane.
Learn MoreControl the environment around extraction, filtration and analysis work.
Learn MoreDiscuss CTC-S10, CTC-SU10, ISO 16232 workflows, OEM cleanliness requirements and automation needs with Conation.